NR 466.02(14) (14) “Month" means a calendar month or a prespecified period of 28 days to 35 days.
NR 466.02(15) (15) “Never-controlled work station" means a work station which is not equipped with provisions by which any emissions, including those in the exhaust from any associated dryer, may be delivered to a control device.
NR 466.02(16) (16) “Overall organic HAP control efficiency" means the total efficiency of a control system, determined either by the product of the capture efficiency and the control device efficiency or a liquid-liquid material balance.
NR 466.02(17) (17) “Print station" means a work station on which a printing operation is conducted.
NR 466.02(18) (18) “Printing operation" means the formation of words, designs and pictures on a substrate other than fabric through the application of material to that substrate.
NR 466.02(19) (19) “Product and packaging rotogravure printing" means the production, on a rotogravure press, of any printed substrate not otherwise defined as publication rotogravure printing. This includes, but is not limited to, folding cartons, flexible packaging, labels and wrappers, gift wraps, wall and floor coverings, upholstery, decorative laminates and tissue products.
NR 466.02(20) (20) “Proof press" means any device used only to check the quality of the image formation of rotogravure cylinders or flexographic plates, which prints only non-saleable items.
NR 466.02(21) (21) “Publication rotogravure printing" means the production, on a rotogravure press, of any of the following saleable paper products:
NR 466.02(21)(a) (a) Catalogues, including mail order and premium.
NR 466.02(21)(b) (b) Direct mail advertisements, including circulars, letters, pamphlets, cards, and printed envelopes.
NR 466.02(21)(c) (c) Display advertisements, including general posters, outdoor advertisements, car cards, window posters; counter and floor displays; and point of purchase and other printed display material.
NR 466.02(21)(d) (d) Magazines.
NR 466.02(21)(e) (e) Miscellaneous advertisements, including brochures, pamphlets, catalog sheets, circular folders, announcements, package inserts, book jackets, market circulars, magazine inserts and shopping news.
NR 466.02(21)(f) (f) Newspapers, magazine and comic supplements for newspapers, and preprinted newspaper inserts, including hi-fi and spectacolor rolls and sections.
NR 466.02(21)(g) (g) Periodicals.
NR 466.02(21)(h) (h) Telephone and other directories, including business reference services.
NR 466.02(22) (22) “Research or laboratory equipment" means any equipment for which the primary purpose is to conduct research and development into new processes and products, where the equipment is operated under the close supervision of technically trained personnel and is not engaged in the manufacture of products for commercial sale in commerce, except in a de minimis manner.
NR 466.02(23) (23) “Rotogravure press" means an unwind or feed section, a series of one or more work stations, one or more of which is a rotogravure print station, any dryers associated with the work stations, and a rewind, stack or collection section. Inboard and outboard work stations including those employing any other technology, such as flexography, are included if they are capable of printing or coating on the same substrate.
NR 466.02(24) (24) “Rotogravure print station" means a work station on which a rotogravure printing operation is conducted. A rotogravure print station includes both a cylinder on which the image, type and art, to be printed is etched or engraved below the surface of the cylinder, and an ink supply.
NR 466.02(25) (25) “Stand-alone coating equipment" means an unwind or feed section, a series of one or more coating stations and any associated dryers, and a rewind, stack or collection section that is not part of a product and packaging rotogravure or wide-web flexographic press, but is used to conduct one or more coating operations on a substrate. Stand-alone coating equipment may or may not do any of the following:
NR 466.02(25)(a) (a) Process substrate that is also processed by a product and packaging rotogravure or wide-web flexographic press.
NR 466.02(25)(b) (b) Apply solids-containing materials that are also applied by a product and packaging rotogravure or wide-web flexographic press.
NR 466.02(25)(c) (c) Utilize a control device that is also utilized by a product and packaging rotogravure or wide-web flexographic press.
NR 466.02 Note Note: Stand-alone coating equipment is sometimes referred to as “off-line" coating equipment.
NR 466.02(26) (26) “Wide-web flexographic press" means a flexographic press capable of printing substrates greater than 18 inches in width.
NR 466.02(27) (27) “Work station" means a unit on a rotogravure or wide-web flexographic press where material is deposited onto a substrate.
NR 466.02 History History: Cr. Register, March, 2000, No. 531, eff. 4-1-00.
NR 466.03 NR 466.03Symbols. The symbols used in equations in this chapter have the following meanings:
NR 466.03(1) (1) Cahi is the monthly average, as-applied, organic HAP content of solids-containing material, i, expressed as a weight-fraction, in kg/kg (lb/lb).
NR 466.03(2) (2) Casi is the monthly average, as applied, solids content of solids-containing material, i, expressed as a weight-fraction, in kg/kg (lb/lb).
NR 466.03(3) (3) Chi is the organic HAP content of solids-containing material, i, expressed as a weight-fraction, in kg/kg (lb/lb).
NR 466.03(4) (4) Chij is the organic HAP content of solvent j, added to solids-containing material i, expressed as a weight-fraction, in kg/kg (lb/lb).
NR 466.03(5) (5) Chj is the organic HAP content of solvent j, expressed as a weight-fraction, in kg/kg (lb/lb).
NR 466.03(6) (6) Ci is the organic volatile matter concentration in ppm, dry basis, of compound i in the vent gas, as determined by Method 25 or Method 25A in 40 CFR Part 60, Appendix A, incorporated by reference in s. NR 484.04.
NR 466.03(7) (7) Csi is the solids content of solids-containing material, i, expressed as a weight-fraction, in kg/kg (lb/lb).
NR 466.03(8) (8) Cvi is the volatile matter content of solids-containing material, i, expressed as a weight-fraction, in kg/kg (lb/lb).
NR 466.03(9) (9) E is the organic volatile matter control efficiency of the control device, expressed as a percent.
NR 466.03(10) (10) F is the organic volatile matter capture efficiency of the capture system as a percent.
NR 466.03(11) (11) Gi is the mass fraction of each solids-containing material, i, which was applied at 20% by weight or greater solids content, on an as-applied basis, in kg/kg (lb/lb).
NR 466.03(12) (12) H is the total monthly organic HAP applied, in kg (lb).
NR 466.03(13) (13) Ha is the monthly allowable organic HAP emissions, in kg (lb).
NR 466.03(14) (14) HL is the monthly average, as-applied, organic HAP content of all solids-containing materials applied at less than 0.04 kg organic HAP per kg of material applied (0.04 lb/lb), in kg/kg (lb/lb).
NR 466.03(15) (15) Hs is the monthly average, as-applied, organic HAP to solids ratio, kg organic HAP/kg solids applied (lb/lb).
NR 466.03(16) (16) Hsi is the as-applied, organic HAP to solids ratio of material i.
NR 466.03(17) (17) L is the mass organic HAP emission rate per mass of solids applied, in kg/kg (lb/lb).
NR 466.03(18) (18) MBi is the sum of the mass of solids-containing material, i, applied on intermittently-controllable work stations operating in bypass mode and the mass of solids-containing material, i, applied on never-controlled work stations, in a month, in kg (lb).
NR 466.03(19) (19) MBj is the sum of the mass of solvent, thinner, reducer, diluent or other non-solids-containing material, j, applied on intermittently-controllable work stations operating in bypass mode and the mass of solvent, thinner, reducer, diluent or other non-solids-containing material, j, applied on never-controlled work stations, in a month, in kg (lb).
NR 466.03(20) (20) MCi is the sum of the mass of solids-containing material, i, applied on intermittently-controllable work stations operating in controlled mode and the mass of solids-containing material, i, applied on always-controlled work stations, in a month, in kg (lb).
NR 466.03(21) (21) MCj is the sum of the mass of solvent, thinner, reducer, diluent or other non-solids-containing material, j, applied on intermittently-controllable work stations operating in controlled mode and the mass of solvent, thinner, reducer, diluent or other non-solids-containing material, j, applied on always-controlled work stations in a month, in kg (lb).
NR 466.03(22) (22) Mf is the total organic volatile matter mass flow rate, in kg/hr (lb/hr).
NR 466.03(23) (23) Mfi is the organic volatile matter mass flow rate at the inlet to the control device, in kg/hr (lb/hr).
NR 466.03(24) (24) Mfo is the organic volatile matter mass flow rate at the outlet of the control device, in kg/hr (lb/hr).
NR 466.03(25) (25) Mhu is the mass of organic HAP used in a month, in kg (lb).
NR 466.03(26) (26) Mi is the mass of solids-containing material, i, applied in a month, in kg (lb).
NR 466.03(27) (27) Mij is the mass of solvent, thinner, reducer, diluent or other non-solids-containing material, j, added to solids-containing material, i, in a month, in kg (lb).
NR 466.03(28) (28) Mj is the mass of solvent, thinner, reducer, diluent or other non-solids-containing material, j, applied in a month, in kg (lb).
NR 466.03(29) (29) MLj is the mass of solvent, thinner, reducer, diluent or other non-solids-containing material, j, added to solids-containing materials which were applied at less than 20% by weight solids content, on an as-applied basis, in a month, in kg (lb).
NR 466.03(30) (30) Mvr is the mass of volatile matter recovered in a month, in kg (lb).
NR 466.03(31) (31) Mvu is the mass of volatile matter, including water, used in a month, in kg (lb).
NR 466.03(32) (32) MWi is the molecular weight of compound i in the vent gas, kg/kg-mol.
NR 466.03(33) (33) n is the number of organic compounds in the vent gas.
NR 466.03(34) (34) p is the number of different inks, coatings, varnishes, adhesives, primers and other solids-containing materials applied in a month.
NR 466.03(35) (35) q is the number of different solvents, thinners, reducers, diluents or other non-solids-containing materials applied in a month.
NR 466.03(36) (36) Qsd is the volumetric flow rate of gases entering or exiting the control device in dscm/hr, as determined by Method 2 in 40 CFR Part 60, Appendix A, incorporated by reference in s. NR 484.04.
NR 466.03(37) (37) R is the overall organic HAP control efficiency as a percent.
NR 466.03(38) (38) Re is the overall effective organic HAP control efficiency for publication rotogravure as a percent.
NR 466.03(39) (39) Rv is the organic volatile matter collection and recovery efficiency as a percent.
NR 466.03(40) (40) S is the mass organic HAP emission rate per mass of material applied, in kg/kg (lb/lb).
NR 466.03(41) (41) 0.0416 is the conversion factor for molar volume, kg-mol/m3, at standard conditions.
NR 466.03 History History: Cr. Register, March, 2000, No. 531, eff. 4-1-00.
NR 466.05 NR 466.05Standards: general. General provisions of ch. NR 460 apply to owners and operators of affected sources subject to this chapter as indicated in ch. NR 460 Appendix KK.
NR 466.05 History History: Cr. Register, March, 2000, No. 531, eff. 4-1-00.
NR 466.06 NR 466.06Standards: publication rotogravure printing.
NR 466.06(1)(1)Compliance dates. Each owner or operator of any publication rotogravure printing affected source that is subject to the requirements of this chapter shall comply with this section on and after the compliance dates as specified in s. NR 466.08.
NR 466.06(2) (2)Emission limitation. The owner or operator of each publication rotogravure affected source shall limit organic HAP emissions to no more than 8% of the total volatile matter used each month.
NR 466.06(3) (3)Compliance methods. The emission limitation in sub. (2) shall be achieved by any of the following methods:
NR 466.06(3)(a) (a) Overall control of at least 92% of organic HAP used.
NR 466.06(3)(b) (b) Substitution of non-HAP materials for organic HAP.
NR 466.06(3)(c) (c) A combination of capture and control technologies and substitution of materials.
NR 466.06(4) (4)Compliance demonstration.
NR 466.06(4)(a)(a) Solvent recovery. Each owner or operator using a solvent recovery device to control emissions shall demonstrate compliance by showing that the HAP emission limitation is achieved by doing either of the following:
NR 466.06(4)(a)1. 1. Perform a liquid-liquid material balance for each month according to the following procedures:
NR 466.06(4)(a)1.a. a. Measure the mass of each ink, coating, varnish, adhesive, primer, solvent and other material used by the affected source during the month.
NR 466.06(4)(a)1.b. b. Determine the organic HAP content of each ink, coating, varnish, adhesive, primer, solvent and other material used by the affected source during the month following the procedure in s. NR 466.09 (2) (a).
NR 466.06(4)(a)1.c. c. Determine the volatile matter content, including water, of each ink, coating, varnish, adhesive, primer, solvent and other material used by the affected source during the month following the procedure in s. NR 466.09 (3) (a).
NR 466.06(4)(a)1.d. d. Install, calibrate, maintain and operate, according to the manufacturer's specifications, a device that indicates the cumulative amount of volatile matter recovered by the solvent recovery device on a monthly basis. The device shall be initially certified by the manufacturer to be accurate to within +2.0%.
NR 466.06(4)(a)1.e. e. Measure the amount of volatile matter recovered for the month.
NR 466.06(4)(a)1.f. f. Calculate the overall effective organic HAP control efficiency (Re) for the month using Equation 1. For the purposes of this calculation, the mass fraction of organic HAP present in the recovered volatile matter is assumed to be equal to the mass fraction of organic HAP present in the volatile matter used.
Loading...
Loading...
Published under s. 35.93, Stats. Updated on the first day of each month. Entire code is always current. The Register date on each page is the date the chapter was last published.